Skip to main content

London P&I Club issues warning

Published by , Digital Assistant Editor
World Coal,


The London P&I Club has issued a warning about continued problems with the carriage of Indonesian thermal coal, after recent incidents involving owners and charterers.

Indonesian coal is prone to self-heat and/or emit methane, can lead to serious cargo fires, and an accumulation of methane can explode. The IMSBC Code states that coal with such characteristics should not be loaded if the temperature of the cargo exceeds 55ºC, and that the atmosphere in the holds is monitored at least daily on passage. The oxidisation process that can lead to self-heating can be detected by checking the hold atmosphere for rising levels of carbon monoxide (CO) and falling oxygen (O2) levels.

The IMSBC Code recommends that the ship carries a means of measuring cargo temperature, and requires that the ship is fitted with gas sampling ports.

Cases recently reported to the club have highlighted the need for thermometers and gas sampling equipment to be regularly serviced and calibrated in accordance with the manufacturer’s instructions. In one case in which the club was acting for charterers, the club-appointed surveyor arrived on board more than a week after the commencement of loading, only to find that a dispute over safety to load had in part been based on readings from equipment, which did not have a valid calibration certificate.

London Club Loss Prevention Manager, Carl Durow, said: “Care should be exercised in interpreting methane measurements carried out in the low O2 concentrations often found in unventilated cargo holds. Typically, manufacturers advise that methane readings will be meaningless if the O2 level falls below 10 per cent. But the club has seen evidence of ships’ staff relying on methane readings even when O2 levels have fallen to negligible levels (one per cent or less). In order to obtain meaningful information, measurements should be made via an approved sample point. The club has seen samples drawn through hold access hatches, which undermines the reliability of the measurements.”

“The atmosphere in the space above the cargo should be regularly monitored – and this may mean that measurements continue after arrival at the discharge port, particularly when discharge is slow. The club has seen problems with both self-heating and methane release worsening markedly during interrupted unloading.”

Edited from press release by

Read the article online at: https://www.worldcoal.com/coal/29042016/london-p-i-club-issues-warning-697/

You might also like

EMI

Electrification in Mining virtual conference

Join us on 16 April 2024 for Global Mining Review's first Electrification in Mining event is an interactive virtual conference, focusing on electrification as the future of sustainable mining and exploring the innovative approaches and technologies being developed to facilitate its implementation.

Register for FREE »

 
 
 

Embed article link: (copy the HTML code below):